CASE STUDY OF INDIRECT HOT AIR GENERATOR

Plant Capacity 20,00,000 K Cal/ Hr
Air Temperature 200 °C
Application Drier
Industry Ceramic Industry

Let us take an example of a 20,00,000 k Cal/Hr plant, with output air at about 200 °C

 

Existing With our Indirect Hot Air Generator
Fuel used LPG Furnace Oil Coal Lignite Agrowaste
Fuel Consumption /day 5500 L 4000 kg 16000 Kg 19000 kg 18000 Kg
Cost of the fuel /day (Rs/Day) 1,75,000 2,08,000 64,000 57,000 63,000
Addl cost of Power & Labour / day (Rs/day) 3,000 3,000 8,000 10,000 10,000
Total Running Costs /day (Rs/day) 1,78,000 2,11,000 72,000 67,000 73000
NET SAVINGS / day (As against Furnace Oil) 1,06,000 1,11,000 1,05,000
NET SAVINGS / day (As against LPG) 1,39,000 1,44,000 1,38,000
Cost of a 20L Plant 60,00,000
Payback Period 56.6 days 54.05 days 57.14 days
Payback Months 2 Months 2 Months 2 Months